Product Details | DIRECTIONAL COUPLER

5985-01-497-9731 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Part Alternates: 4016C20, 4016C-20, 51501003, 5150-1003, 5985-01-497-9731, 01-497-9731, 5985014979731, 014979731

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 10 JUN 2002 01-497-9731

Cross Reference | NSN 5985-01-497-9731

Part Number Cage Code Manufacturer
4016C-20 99899 L-3 COMMUNICATIONS CORPORATION DBA NARDA MICROWAVE EAST
5150-1003 K0662 SELEX ES LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-497-9731

Technical Data | NSN 5985-01-497-9731

Characteristic Specifications
UNIT TYPE COAXIAL LINE
RADIO FREQUENCY RATING 12.4 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY 1.3 TO 1 AT 12.4 TO 18.0 GHZ; 1.4 TO 1 AT 12.4 TO 18.0 GHZ ON SECONDARY LINE
DESIGN TYPE BIDIRECTIONAL OR UNIDIRECTIONAL
POWER LOSS IN DECIBELS NOT RATED
OVERALL LENGTH 2.050 INCHES MAXIMUM
OVERALL WIDTH 0.520 INCHES MAXIMUM
OVERALL HEIGHT 1.580 INCHES MAXIMUM
SPECIAL FEATURES THERE SHALL BE TWO HOLES DRILLED THROUGH ITEM AT A DIAMETER OF 0.123 INCHES TO 0.129 INCHES
TEST DATA DOCUMENT 81349-MIL-C-15370 SPECIFICATION

Restrictions/Controls & Freight Information | NSN 5985-01-497-9731

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information