Product Details | ELECTRICAL DUMMY LOAD

5985-01-426-4368 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Part Alternates: 2002551, 200255-1, 5985-01-426-4368, 01-426-4368, 5985014264368, 014264368

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 12 MAR 1996 01-426-4368

Cross Reference | NSN 5985-01-426-4368

Part Number Cage Code Manufacturer
200255-1 0H3E9 NVISION INDUSTRIES, INC. DBA WEINSCHEL ASSOCIATES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-426-4368

Technical Data | NSN 5985-01-426-4368

Characteristic Specifications
FREQUENCY RANGE RATING 0.000 TO 2.500 GIGAHERTZ
POWER RATING 1000.000 WATTS PEAK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER -40.0 AND 45.0
VOLTAGE STANDING WAVE RATIO 1.10 AND 1.25
TERMINATION TYPE CONNECTION COAXIAL
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
SPECIAL FEATURES ALUMINUM BODY & FINS; QUICK-CHANGE FEMALE CONNECTOR
III END ITEM IDENTIFICATION COMMON

Restrictions/Controls & Freight Information | NSN 5985-01-426-4368

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 060535 AERIAL/ANTENNAS DIRECTIONAL
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TK HQ AFMC/GLSC 401 SCM/GUMB
Wright-Patterson AFB, OH 45433-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-426-4368

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeQCTG:ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityUAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each