NSN 5985-01-216-2056 SMD956891, SM-D-956891, 01-216-2056
Product Details | COAXIAL CRYSTAL MIXER
5985-01-216-2056 An item consisting of coaxial line and associated connectors having two frequency inputs, a crystal (any semiconductor device that provides rectification) and an output connection. It is employed to mix two frequencies, with the resultant output frequency being a composite of the two inputs. For items utilizing electron tube(s) and/or WAVEGUIDE ASSEMBLY, see MIXER STAGE, FREQUENCY; and MIXER, CRYSTAL, WAVEGUIDE.
Part Alternates: SMD956891, SM-D-956891, 5985-01-216-2056, 01-216-2056, 5985012162056, 012162056
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 07 SEP 1985 | 01-216-2056 | 22970 ( MIXER, CRYSTAL, COAXIAL ) |
Cross Reference | NSN 5985-01-216-2056
Part Number | Cage Code | Manufacturer |
---|---|---|
SM-D-956891 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-01-216-2056
Related Products | NSN 5985-01-216-2056
Technical Data | NSN 5985-01-216-2056
Characteristic | Specifications |
---|---|
III END ITEM IDENTIFICATION | RELAY AND TRANSMISSION EQUIP |
Restrictions/Controls & Freight Information | NSN 5985-01-216-2056
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | Y | COMMUNICATION/ELECTRONIC EQUIPMENT AND PARTS |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | W | Rating Variable |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-01-216-2056
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | G | Communications and Electronics Equipment, Electronics Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 4 | PROVISIONING ITEMS (Exclusive of Insurance Items). This code will identify new items introduced through the provisioning process for system stock which would normally be categorized as either nonreparable or reparable but for which sufficient experience has been obtained to manage on the basis of normal demand forecasts. |
Specific Group/Generic Code | R | Tactical and Strategic Communications |
Weapons Systems/End Item or Homogeneous Group | RF | Multi-channel Radios C |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DA | Department of the Army |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | D | When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | Y | COMMUNICATION/ELECTRONIC EQUIPMENT AND PARTS |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |