Product Details | ELECTRICAL DUMMY LOAD

5985-01-188-8573 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Part Alternates: RCX1SM, T180M, 04630121, 0463012-1, 0512760001, 051276-0001, 5985-01-188-8573, 01-188-8573, 5985011888573, 011888573

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 08 SEP 1984 01-188-8573

Drawings & Photos | NSN 5985-01-188-8573


Demand History | NSN 5985-01-188-8573

Part Number Request Date QTY Origin
5985-01-188-8573 2010-07-183 11 DIBBS

Cross Reference | NSN 5985-01-188-8573

Part Number Cage Code Manufacturer
0463012-1 24587 RAYTHEON CO ESD LONG ISLAND DIV
051276-0001 65597 THALES DEFENSE & SECURITY, INC.
RCX1SM 0C3F5 RES-NET MICROWAVE, INC.
T180M 64537 AEROFLEX CONTROL COMPONENTS, INC. DBA AEROFLEX / KDI

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-188-8573

Technical Data | NSN 5985-01-188-8573

Characteristic Specifications
STYLE DESIGNATOR 4A COAXIAL MOUNTED
OVERALL LENGTH 0.410 INCHES NOMINAL
OVERALL DIAMETER 0.250 INCHES NOMINAL
FREQUENCY RANGE RATING 0.000 TO 18.000 GIGAHERTZ
POWER RATING 0.500 WATTS AVERAGE
IMPEDANCE RATING IN OHMS 50.0 NOMINAL
VOLTAGE STANDING WAVE RATIO 1.15
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE 0.000 TO 18.000 GIGAHERTZ
TERMINATION TYPE CONNECTION COAXIAL
COAXIAL CONNECTOR SERIES DESIGNATION SMA
CONNECTOR END DESIGN MALE
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS

Restrictions/Controls & Freight Information | NSN 5985-01-188-8573

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-188-8573

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each