Product Details | COAXIAL CRYSTAL MIXER

5985-01-178-7841 An item consisting of coaxial line and associated connectors having two frequency inputs, a crystal (any semiconductor device that provides rectification) and an output connection. It is employed to mix two frequencies, with the resultant output frequency being a composite of the two inputs. For items utilizing electron tube(s) and/or WAVEGUIDE ASSEMBLY, see MIXER STAGE, FREQUENCY; and MIXER, CRYSTAL, WAVEGUIDE.

Part Alternates: MX4001, 5985-01-178-7841, 01-178-7841, 5985011787841, 011787841

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 10 MAY 1984 01-178-7841

Cross Reference | NSN 5985-01-178-7841

Part Number Cage Code Manufacturer
MX4001 14844 FREQUENCY ELECTRONICS, INC. DIV FREQUENCY ELECTRONICS, INC.
MX4001 21847 FEI MICROWAVE INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-178-7841

Technical Data | NSN 5985-01-178-7841

Characteristic Specifications
FREQUENCY RANGE RATING 2.0 TO 4.0 GIGAHERTZ
INSERTION LOSS IN DECIBELS 7.5
SIGNAL INPUT TERMINAL DESIGNATOR SMA FEMALE CONNECTOR
LOCAL OSCILLATOR INPUT TERMINAL DESIGNATOR SMA FEMALE CONNECTOR
SIGNAL OUTPUT TERMINAL DESIGNATOR SMA FEMALE CONNECTOR
LOCAL OSCILLATOR INPUT ADJUSTABILITY NONADJUSTABLE
OVERALL LENGTH 1.840 INCHES NOMINAL
OVERALL WIDTH 1.415 INCHES NOMINAL
OVERALL HEIGHT 1.000 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5985-01-178-7841

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information