NSN 5985-01-165-2741 MPS686, MPS-686, 5176479
Product Details | DIRECTIONAL COUPLER
5985-01-165-2741 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.
Part Alternates: MPS686, MPS-686, 5176479, 5985-01-165-2741, 01-165-2741, 5985011652741, 011652741
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 27 OCT 1983 | 01-165-2741 | 00384 ( COUPLER, DIRECTIONAL ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-01-165-2741
Related Products | NSN 5985-01-165-2741
Technical Data | NSN 5985-01-165-2741
Characteristic | Specifications |
---|---|
UNIT TYPE | COAXIAL LINE OR TRANSMISSION LINE |
RADIO FREQUENCY RATING | 8.9 GIGAHERTZ MINIMUM AND 9.4 GIGAHERTZ MAXIMUM |
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY | 1.25 TO 1 AT 8.9 TO 9.4 GHZ |
DESIGN TYPE | BIDIRECTIONAL |
POWER LOSS IN DECIBELS | 3.0 |
TERMINAL FITTING NAME | TNC FEMALE CONNECTOR |
TERMINAL FITTING USAGE DESIGN | MAIN LINE AND SECONDARY LINE |
OVERALL LENGTH | 4.750 INCHES NOMINAL |
OVERALL WIDTH | 4.500 INCHES NOMINAL |
OVERALL HEIGHT | 0.750 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5985-01-165-2741
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 723 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-01-165-2741
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |