Product Details | DIRECTIONAL COUPLER

5985-01-156-8959 An item specifically designed to be inserted into a transmission line, waveguide or coaxial transmission line to provide a suitable test outlet. The test signal is attenuated to a predetermined value.

Part Alternates: CH 650, CH650, CRM-10-500/28248, CRM1050028248, 9262511B, 926251-1B, 5985-01-156-8959, 01-156-8959, 5985011568959, 011568959

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 27 JUN 1983 01-156-8959

Cross Reference | NSN 5985-01-156-8959

Part Number Cage Code Manufacturer
926251-1B 82577 RAYTHEON COMPANY DBA RAYTHEON
CH 650 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS
CRM-10-500/28248 12457 MERRIMAC INDUSTRIES, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-156-8959

Technical Data | NSN 5985-01-156-8959

Characteristic Specifications
UNIT TYPE COAXIAL LINE OR TRANSMISSION LINE
RADIO FREQUENCY RATING 0.03 GIGAHERTZ MINIMUM AND 1.00 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO AT REFERENCE FREQUENCY 1.35 TO 1 AT 0.03 TO 1.00 GHZ
DESIGN TYPE BIDIRECTIONAL
POWER LOSS IN DECIBELS NOT RATED
TERMINAL FITTING NAME SMA CONNECTOR
TERMINAL FITTING CONTROLLING AGENCY DEPARTMENT OF DEFENSE
TERMINAL FITTING USAGE DESIGN MAIN LINE AND SECONDARY LINE
OVERALL LENGTH 2.144 INCHES NOMINAL
OVERALL WIDTH 1.744 INCHES NOMINAL
OVERALL HEIGHT 0.750 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5985-01-156-8959

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-156-8959

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative