NSN 5985-00-901-5577 DA229GRM21, 302D1000, 5222007005
Product Details | ELECTRICAL DUMMY LOAD
5985-00-901-5577 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.
Part Alternates: DA229GRM21, 302D1000, 5222007005, 522-2007-005, 5985-00-901-5577, 00-901-5577, 5985009015577, 009015577
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1960 | 00-901-5577 | 00335 ( DUMMY LOAD, ELECTRICAL ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5985-00-901-5577
Technical Data | NSN 5985-00-901-5577
Characteristic | Specifications |
---|---|
FREQUENCY RANGE RATING | 2.000 TO 30.000 MEGAHERTZ |
POWER RATING | 1.000 KILOWATTS PEAK AND 500.000 WATTS AVERAGE |
IMPEDANCE RATING IN OHMS | NOT RATED |
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | 2.000 TO 30.000 MEGAHERTZ |
COOLING METHOD | SELF-COOLED |
Restrictions/Controls & Freight Information | NSN 5985-00-901-5577
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | J | 100.2 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 653 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-00-901-5577
Category | Code | Description |
---|---|---|
Stores Account Code | 2 | Marine Corps Appropriation Stores Account Secondary Items. |
Combat Essentiality Code | 0 | Non-combat Essential End Item. End items that do not fit the definition of Code 1 items. |
Materiel Management Code | 4 | Communications/Electronics Materiel5445, 58, 59, 60, 61, 6625, 6660, 6665 |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Echelon Identification Code | C | Type 2 (as required items) |
Operational Test Code | 2 | Items of equipment which require the performance of special procedures are not controlled through the MOWASP special handling suspense routine by USMC/Serial Numbers, (except small arms which are controlled by serial numbers but are assigned OTC 2). Normally OTC 2 items of equipments are small arms, engines (except small engines coded SAC-1 which are non-technical), pumps, generators, electronic equipments and major components/subassemblies of weapon systems, etc. Electronic Circuit Cards and other items which have received Level A packing will only be assigned an OTC when an operational test is mandatory prior to issue. |
Source of Supply | MPB | Commanding General Marine Corps Logistics Command 566-2, Bldg. 3700 Albany, GA 31704-5000 |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | D | Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level. |
Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |