Product Details | FEEDTHRU INSULATOR

5970-00-076-3289 An insulator which is specifically designed to provide for the passage of electrical conductors through such items as panels, bulkheads, walls, and the like. It consists of two or more insulators, including one or more studs fed through the items in such a way as to be used as conductors. The studs may be used for mounting. See also INSULATOR, BOWL; and TERMINAL, FEEDTHRU, INSULATED.

Part Alternates: 20492, 5970-00-076-3289, 00-076-3289, 5970000763289, 000763289

Electrical and Electronic Equipment Components | Electrical Insulators and Insulating Materials

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-076-3289

Cross Reference | NSN 5970-00-076-3289

Part Number Cage Code Manufacturer
20492 04108 COOPER INDUSTRIES INC MCGRAW-EDISON POWER SYSTEMS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5970-00-076-3289

Technical Data | NSN 5970-00-076-3289

Characteristic Specifications
OUTSIDE DIAMETER 8.688 INCHES NOMINAL
MOUNTING HOLE DIAMETER 0.562 INCHES NOMINAL
HEIGHT ABOVE MOUNTING SURFACE 9.625 INCHES NOMINAL
CENTER STUD LENGTH 24.249 INCHES NOMINAL
MATERIAL AND LOCATION OVERALL PORCELAIN
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
SCREW THREAD SERIES DESIGNATOR AND LOCATION CENTER STUD UNC
SCREW THREAD DIAMETER AND LOCATION 0.750 CENTER STUD INCHES NOMINAL
SCREW THREAD QUANTITY PER INCH AND LOCATION 10 CENTER STUD
THREAD CLASS AND LOCATION 2A CENTER STUD
MANUFACTURERS CODE 04108
DESIGN CONTROL REFERENCE 20492

Restrictions/Controls & Freight Information | NSN 5970-00-076-3289

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 103745 ELECTRIC WIRE OR WIRING
Less than car load rating
Less than truck load rating T 55.0
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5970-00-076-3289

Category Code Description
Cognizance Codes9GNavy-owned stocks of defense general material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9GDefense Supply Center Richmond
Richmond, VA 23297
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each