Product Details | LINEAR MICROCIRCUIT

5962-01-590-8785 A microcircuit whose output is a function of the input; that is, the output varies in a predetermined and essentially predictable manner from the input signal.

Part Alternates: MAX6225AEPA, 5962-01-590-8785, 01-590-8785, 5962015908785, 015908785

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 29 DEC 2010 01-590-8785

Cross Reference | NSN 5962-01-590-8785

Part Number Cage Code Manufacturer
MAX6225AEPA 1ES66 MAXIM INTEGRATED PRODUCTS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-590-8785

Technical Data | NSN 5962-01-590-8785

Characteristic Specifications
PART NAME ASSIGNED BY CONTROLLING AGENCY CAGE: LOW-NOISE, PRECISION, +2.5V VOLTAGE REFERENCE
DESIGN FUNCTION AND QUANTITY 1 REFERENCE, VOLTAGE, ANALOG
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 8.0 VOLTS MINIMUM INPUT AND 36.0 VOLTS MAXIMUM INPUT AND 2.5 VOLTS NOMINAL OUTPUT
SPECIAL FEATURES BURIED ZENER TECHNOLOGY FOR LOWEST NOISE PERFORMANCE
BODY WIDTH 0.300 INCHES MINIMUM AND 0.325 INCHES MAXIMUM
BODY LENGTH 0.348 INCHES MINIMUM AND 0.390 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 8 PIN
OPERATING TEMP RANGE -40.0/+85.0 DEG CELSIUS
STORAGE TEMP RANGE -65.0/+150.0 DEG CELSIUS
BODY HEIGHT 0.200 INCHES MAXIMUM
INCLOSURE CONFIGURATION DUAL-IN-LINE

Restrictions/Controls & Freight Information | NSN 5962-01-590-8785

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information