Product Details | MEMORY MICROCIRCUIT

5962-01-466-4873 A circuit designed to store information and/or coded instructions. Item has pins or other connections to install in a computer or computing device. Does not include magnetic drums, tapes, punched cards or the like. For items that have portable type connections see MEMORY, PORTABLE, SOLID STATE.

Part Alternates: 93793563, 9379356-3, 5962-01-466-4873, 01-466-4873, 5962014664873, 014664873

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 21 JUL 1999 01-466-4873

Cross Reference | NSN 5962-01-466-4873

Part Number Cage Code Manufacturer
9379356-3 19200 US ARMY ARDEC RDECOM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-466-4873

Technical Data | NSN 5962-01-466-4873

Characteristic Specifications
OUTPUT LOGIC FORM TRANSISTOR-TRANSISTOR LOGIC
INPUT CIRCUIT PATTERN 20 INPUT
VOLTAGE RATING AND TYPE PER CHARACTERISTIC 12.0 VOLTS MAXIMUM MULTIPLEX INPUT SIGNAL
CURRENT RATING PER CHARACTERISTIC 210.00 MILLIAMPERES MAXIMUM SUPPLY
MEMORY DEVICE TYPE PAL
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
TERMINAL TYPE AND QUANTITY 24 PRINTED CIRCUIT
TERMINAL SURFACE TREATMENT SOLDER
INCLOSURE CONFIGURATION DUAL-IN-LINE
INCLOSURE MATERIAL CERAMIC
BODY LENGTH 1.290 INCHES MAXIMUM
BODY HEIGHT 0.210 INCHES MAXIMUM
BODY WIDTH 0.310 INCHES MAXIMUM
MAXIMUM POWER DISSIPATION RATING 1.2 WATTS
STORAGE TEMP RANGE -65.0 TO 150.0 DEG CELSIUS
FEATURES PROVIDED MONOLITHIC AND BIPOLAR AND PROGRAMMABLE
SPECIAL FEATURES ALTERED M38510/50504BLA
TEST DATA DOCUMENT 96906-MIL-STD-883 STANDARD

Restrictions/Controls & Freight Information | NSN 5962-01-466-4873

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 738 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5962-01-466-4873

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each