Product Details | QUARTZ CRYSTAL UNIT

5955-01-014-2306 An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.

Part Alternates: CR-27A/U, CR-27A/U5.228000MHZ, CR27AU, CR27AU5228000MHZ, MIL-C-3098/9, MILC30989, 5955-01-014-2306, 01-014-2306, 5955010142306, 010142306

Electrical and Electronic Equipment Components | Oscillators and Piezoelectric Crystals

Supply Group (FSG) NSN Assign. NIIN
59 17 DEC 1975 01-014-2306

Drawings & Photos | NSN 5955-01-014-2306


Cross Reference | NSN 5955-01-014-2306

Part Number Cage Code Manufacturer
CR-27A/U 71034 BLILEY TECHNOLOGIES INCORPORATED
CR-27A/U5.228000MHZ 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-3098/9 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5955-01-014-2306

Technical Data | NSN 5955-01-014-2306

Characteristic Specifications
MODE OF OSCILLATION FUNDAMENTAL
CIRCUIT RESONANCE ANTIRESONANCE
LOAD CAPACITANCE IN PICOFARADS 31.5 MINIMUM AND 32.5 MAXIMUM
SHUNT CAPACITANCE IN PICOFARADS 7.0 MAXIMUM
SPECIFIED FREQUENCY 5.228 MEGAHERTZ
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT -0.002 TO 0.002
OPERATING TEMP RANGE 70.0 TO 80.0 DEG CELSIUS
CONTROLLED REFERENCE TEMP 75.0 DEG CELSIUS
FREQUENCY TOLERANCE AT REFERENCE TEMP IN PERCENT -0.002 TO 0.002
FREQUENCY STABILITY IN PERCENT -0.0005 TO 0.0005
OPERABLE TEMP RANGE -55.0 TO 90.0 DEG CELSIUS
EQUIVALENT RESISTANCE VALUE IN OHMS 35.0 MAXIMUM
DRIVE LEVEL RATING 4.0 MILLIWATTS MINIMUM AND 6.0 MILLIWATTS MAXIMUM
STYLE DESIGNATOR 1 OVAL BODY, PIN TERMINALS
OVERALL LENGTH 1.023 INCHES MAXIMUM
TERMINAL LENGTH 0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
OVERALL WIDTH 0.757 INCHES MAXIMUM
BODY LENGTH 0.775 INCHES MAXIMUM
BODY WIDTH 0.725 INCHES MAXIMUM
BODY THICKNESS 0.317 INCHES MAXIMUM
OVERALL THICKNESS 0.352 INCHES MAXIMUM
TERMINAL DIAMETER 0.048 INCHES MINIMUM AND 0.052 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS 0.478 INCHES MINIMUM AND 0.494 INCHES MAXIMUM
HOLDER COVER MATERIAL METAL
TEST DATA DOCUMENT 81349-MILC3098 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MILC3098/9 GOVERNMENT SPECIFICATION
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE CR-27A/U5.228000MHZ
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-3098/9

Restrictions/Controls & Freight Information | NSN 5955-01-014-2306

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063025 SEMICONDUCTORS/DEVICES NOI ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5955-01-014-2306

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each