Product Details | ELECTROMAGNETIC RELAY

5945-01-573-7795 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: M83536/1-024R, M835361024R, B6734030AY128, B673-4030-AY-1-28, MIL-PRF-83536/1, MILPRF835361, 5967410894AY128, 596-7410894-AY-1-28, 5945-01-573-7795, 01-573-7795, 5945015737795, 015737795

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 05-MAY-09 01-573-7795

Cross Reference | NSN 5945-01-573-7795

Part Number Cage Code Manufacturer
596-7410894-AY-1-28 53711 NAVAL SEA SYSTEMS COMMAND
B673-4030-AY-1-28 96169 ELECTRIC BOAT CORPORATION
M83536/1-024R 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-83536/1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-573-7795

Technical Data | NSN 5945-01-573-7795

Characteristic Specifications
WINDING DC RESISTANCE RATING 500.0 OHMS NOMINAL SINGLE WINDING
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
OVERALL LENGTH 1.260 INCHES MINIMUM AND 1.280 INCHES MAXIMUM
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
SPECIFICATION/STANDARD DATA 81349-MIL-PRF-83536/1 GOVERNMENT SPECIFICATION
OVERALL HEIGHT 0.620 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
FAILURE RATE SUFFIX LETTER R
TIME DELAY 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
MOUNTING SLOT WIDTH 0.133 INCHES NOMINAL SINGLE MOUNTING FACILITY
SPECIAL FEATURES INAVY-RELAY MAGNETIC DPDT; OPERATION TEMP RANGE: -70 TO +125 DEG CELCIUS
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
ARC QUENCHING METHOD AIR
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC MOTOR LOAD AND 2.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 3.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD
TEST DATA DOCUMENT 81349-MIL-PRF-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
COIL QUANTITY 1
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
FEATURES PROVIDED POLARIZED
WINDING QUANTITY 1
END ITEM IDENTIFICATION PANEL ASSY, PORT DOOR IND, 596-7410894-AY-1; WSD: SEAWOLF CLASS SSN
CASE MATERIAL METAL
FRAGILITY FACTOR MODERATELY RUGGED
MOUNTING FACILITY TYPE AND QUANTITY 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
PURPOSE FOR WHICH DESIGNED GENERAL
DUTY TYPE CONTINUOUS
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
ENVIRONMENTAL PROTECTION HERMETIC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY
OVERALL WIDTH 0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM

Restrictions/Controls & Freight Information | NSN 5945-01-573-7795

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information