Product Details | ELECTROMAGNETIC RELAY

5945-01-482-8724 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: T90S1D125, T90S1D12-5, 5945-01-482-8724, 01-482-8724, 5945014828724, 014828724

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 07 MAR 2001 01-482-8724

Cross Reference | NSN 5945-01-482-8724

Part Number Cage Code Manufacturer
T90S1D12-5 77342 TYCO ELECTRONICS CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-482-8724

Technical Data | NSN 5945-01-482-8724

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 240.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 20.0 AMPERES DC AND 30.0 AMPERES AC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 27.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
NOMINAL OPERATING CURRENT RATING AND TYPE 185.0 MILLIAMPERES DC ALL WINDINGS
TERMINAL TYPE AND QUANTITY 5 PIN ALL FUNCTIONS
DUTY TYPE CONTINUOUS
OVERALL LENGTH 1.270 INCHES MAXIMUM
OVERALL WIDTH 1.080 INCHES MAXIMUM
OVERALL HEIGHT 0.805 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY
III END ITEM IDENTIFICATION ALQ172V3SED/; AIRCRAFT, (AC-130H, MC-130H, EC-130E, HC-130)

Restrictions/Controls & Freight Information | NSN 5945-01-482-8724

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-01-482-8724

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeLGTG:C-130 HERCULES
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each