Product Details | ELECTROMAGNETIC RELAY

5945-01-233-1209 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: M39016/15-031P, M3901615031P, MIL-PRF-39016/15, MILPRF3901615, MIL-R-39016/15, MILR3901615, 5945-01-233-1209, 01-233-1209, 5945012331209, 012331209

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 25 MAY 1986 01-233-1209

Cross Reference | NSN 5945-01-233-1209

Part Number Cage Code Manufacturer
M39016/15-031P 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-39016/15 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-39016/15 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-233-1209

Technical Data | NSN 5945-01-233-1209

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 500.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD 200.0 MILLIAMPERES DC INDUCTIVE LOAD
ARC QUENCHING METHOD AIR
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 390.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 8 WIRE LEAD ALL FUNCTIONS
TIME DELAY 0.002 SECONDS MAXIMUM FIXED OPERATE TIME 0.004 SECONDS MAXIMUM FIXED RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 0.280 INCHES MAXIMUM
OVERALL DIAMETER 0.335 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 1 TERMINAL SINGLE MOUNTING FACILITY
FEATURES PROVIDED POLARIZED
SPECIAL FEATURES FAILURE RATE LEVEL 0.1 PERCENT
TEST DATA DOCUMENT 81349-MIL-R-39016 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-39016/15 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATION FEAT
III PURPOSE FOR WHICH DESIGNED GENERAL
III END ITEM IDENTIFICATION AMPLIFIER ELE
(NON-CORE DATA) END ITEM SOURCE 26055
III UNPACKAGED UNIT WEIGHT 0.090 OUNCES
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III CASE MATERIAL METAL
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-PRF-39016/15
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39016/15-031P

Restrictions/Controls & Freight Information | NSN 5945-01-233-1209

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-01-233-1209

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each