Product Details | ELECTROMAGNETIC RELAY

5945-01-123-9663 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: 6957ED243A, 6957ED24-3A, 5945-01-123-9663, 01-123-9663, 5945011239663, 011239663

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 27 DEC 1981 01-123-9663

Demand History | NSN 5945-01-123-9663

Part Number Request Date QTY Origin
6957ED24-3A 2023-07-191 17 DIBBS
6957ED24-3A 2021-04-101 14 DIBBS
6957ED24-3A 2021-03-77 25 DIBBS
5945-01-123-9663 2019-05-142 4 United States
6957ED24-3A 2019-03-73 43 DIBBS
5945-01-123-9663 2018-10-297 7 DIBBS
6957ED243A 2018-03-88 1 Taiwan
5945-01-123-9663 2016-03-63 19 DIBBS
5945-01-123-9663 2013-02-59 14 DIBBS
5945-01-123-9663 2012-08-215 16 DIBBS
5945-01-123-9663 2012-05-125 17 DIBBS
5945-01-123-9663 2012-02-33 20 DIBBS
5945-01-123-9663 2011-12-362 11 DIBBS
6957ED243A 2011-07-207 2 United States
6957ED243A 2011-07-200 2 United States
5945-01-123-9663 2009-02-35 8 DIBBS
5945-01-123-9663 2008-12-351 24 DIBBS
5945-01-123-9663 2008-09-259 29 DIBBS
5945-01-123-9663 2008-04-112 12 DIBBS
5945-01-123-9663 2007-03-89 6 DIBBS

Cross Reference | NSN 5945-01-123-9663

Part Number Cage Code Manufacturer
6957ED24-3A 27192 DRS POWER & CONTROL TECHNOLOGIES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-01-123-9663

Technical Data | NSN 5945-01-123-9663

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 440.0 AC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 15.0 AMPERES AC RESISTIVE LOAD
ARC QUENCHING METHOD AIR
COIL QUANTITY 1
WINDING QUANTITY 1
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 440.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 18 SCREW ALL FUNCTIONS
DUTY TYPE CONTINUOUS
OVERALL LENGTH 4.375 INCHES NOMINAL
OVERALL WIDTH 4.125 INCHES NOMINAL
OVERALL HEIGHT 4.562 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER 0.201 INCHES NOMINAL SINGLE MOUNTING FACILITY
III PURPOSE FOR WHICH DESIGNED GENERAL
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE

Restrictions/Controls & Freight Information | NSN 5945-01-123-9663

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-01-123-9663

Category Code Description
Cognizance Codes3BNavy-owned stocks of field level repairable DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityDField Level Reparables
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each