NSN 5945-01-061-9349 01-061-9349, 010619349
Product Details | ELECTROMAGNETIC RELAY
5945-01-061-9349 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: 5945-01-061-9349, 01-061-9349, 5945010619349, 010619349
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01-061-9349 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Cross Reference | NSN 5945-01-061-9349
Part Number | Cage Code | Manufacturer |
---|---|---|
3SAV1956A2 | 01526 | GENICOM CORP |
93230310-10M | 99699 | DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE |
DJ26N3L6AS-3M | 99699 | DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE |
ERS6B2-26.5-M1 | 02288 | ALLIED CONTROLS, INC. |
J2K-4730-106M | 02289 | HI-G CO INC SUB OF NYTRONICS INC |
M39016/6-106M | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M39016/6-106P | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757/9-010 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-PRF-39016/6 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-R-39016/6 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MILR5757-9 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-01-061-9349
Related Products | NSN 5945-01-061-9349
Technical Data | NSN 5945-01-061-9349
Characteristic | Specifications |
---|---|
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 700.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
TIME DELAY | 0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | DUSTPROOF |
OVERALL LENGTH | 1.320 INCHES MAXIMUM |
OVERALL WIDTH | 0.410 INCHES MAXIMUM |
OVERALL HEIGHT | 0.410 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.062 INCHES MINIMUM AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
SPECIAL FEATURES | FAILURE RATE LEVEL 1.0 PERCENT;FLANGE MTG B |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION |
CRITICALITY CODE JUSTIFICATION | FEAT |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39016/6 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39016/6-106M |
Restrictions/Controls & Freight Information | NSN 5945-01-061-9349
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Category | Code | Description |
---|---|---|
No Freight Information |