NSN 5945-01-025-2624 01-025-2624, 010252624
Product Details | ELECTROMAGNETIC RELAY
5945-01-025-2624 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: 5945-01-025-2624, 01-025-2624, 5945010252624, 010252624
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01-025-2624 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Cross Reference | NSN 5945-01-025-2624
Part Number | Cage Code | Manufacturer |
---|---|---|
J420-5WL | 11532 | TELEDYNE REYNOLDS, INC. DBA TELEDYNE RELAYS |
M39016-12-001L | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M39016/12-001M | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M39016/12-025L | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M39016/12-025P | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
M5757&71&011 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-PRF-39016/12 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-R-39016/12 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-01-025-2624
Related Products | NSN 5945-01-025-2624
Technical Data | NSN 5945-01-025-2624
Characteristic | Specifications |
---|---|
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD 200.0 MILLIAMPERES DC INDUCTIVE LOAD 100.0 MILLIAMPERES DC LAMP LOAD |
COIL QUANTITY | 2 |
WINDING QUANTITY | 2 |
WINDING DC RESISTANCE RATING | 54.9 OHMS MINIMUM AND 67.1 OHMS MAXIMUM ALL WINDINGS |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 5.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS |
TIME DELAY | 0.002 SECONDS MAXIMUM FIXED OPERATE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT AND HERMETIC |
OVERALL LENGTH | 0.280 INCHES MAXIMUM |
OVERALL DIAMETER | 0.275 INCHES MINIMUM AND 0.335 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
SPECIAL FEATURES | FAILURE RATE 3.0 PERCENT PER 10,000 CYCLES |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/12 GOVERNMENT SPECIFICATION |
CRITICALITY CODE JUSTIFICATION | FEAT |
III PURPOSE FOR WHICH DESIGNED | GENERAL |
III CUBIC MEASURE | 0.025 CUBIC INCHES |
III UNPACKAGED UNIT WEIGHT | 0.100 OUNCES |
III FRAGILITY FACTOR | MODERATELY RUGGED |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39016/12 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39016/12-025L |
Restrictions/Controls & Freight Information | NSN 5945-01-025-2624
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Category | Code | Description |
---|---|---|
No Freight Information |