Product Details | ELECTRICAL SOLENOID

5945-00-765-5347 An item consisting of one or more coils surrounding an iron core. The coil(s) and the core are moveable in relation to each other. The axial or rotary movement is a result of the magnetic flux of the coil. It is designed to convert electrical energy into mechanical energy. It does not include switch contacts. See also RELAY, ELECTROMAGNETIC, and ELECTROMAGNETIC ACTUATOR.

Part Alternates: A7794567, B65101001, B65101-001, 7794567, 5945-00-765-5347, 00-765-5347, 5945007655347, 007655347

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-765-5347

Drawings & Photos | NSN 5945-00-765-5347


Demand History | NSN 5945-00-765-5347

Part Number Request Date QTY Origin
5945-00-765-5347 2015-02-42 8 DIBBS
5945-00-765-5347 2014-12-355 8 DIBBS

Cross Reference | NSN 5945-00-765-5347

Part Number Cage Code Manufacturer
7794567 19200 US ARMY ARDEC RDECOM
7794567 19205 SPRINGFIELD ARMORY
A7794567 19204 ARMY UNITED STATES DEPARTMENT OF THE
B65101-001 81840 SAIA-BURGESS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-765-5347

Technical Data | NSN 5945-00-765-5347

Characteristic Specifications
BODY STYLE 15 ARMATURE END ACTUATOR
BODY DIAMETER 1.875 INCHES NOMINAL
BODY HEIGHT 2.254 INCHES NOMINAL
MAGNETIC COIL QUANTITY 1
VOLTAGE RATING IN VOLTS 28.0 DC NOMINAL
ELECTRICAL RESISTANCE 10.30 OHMS NOMINAL
DUTY TYPE CONTINUOUS
ACTUATOR STROKE TYPE ROTARY
ROTATION DIRECTION AND ENERGIZING STROKE IN ANGULAR DEG 12.0 COUNTERCLOCKWISE
TORQUE RATING AND TYPE 7.00 INCH-POUNDS STARTING
ENERGIZING STROKE MAXIMUM LENGTH 0.042 INCHES
POWER TAKEOFF CONNECTION TYPE PLAIN
ACTUATOR DIAMETER 0.156 INCHES NOMINAL
ACTUATOR LENGTH 0.562 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.250 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC MOUNTING FACILITY STUD
NOMINAL THREAD SIZE 0.164 INCHES MOUNTING FACILITY STUD
THREAD CLASS 2A MOUNTING FACILITY STUD
THREAD QUANTITY PER INCH 32 MOUNTING FACILITY STUD
THREAD DIRECTION RIGHT-HAND MOUNTING FACILITY STUD
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
TERMINAL LOCATION CIRCUMFERENCE
INCLOSURE TYPE FULLY INCLOSED
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND FUNGUS RESISTANT AND HUMIDITY RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT
III MAXIMUM OPERATING TEMP 80.0 DEG CELSIUS
III CUBIC MEASURE 6.639 CUBIC INCHES
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5945-00-765-5347

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063100 SOLENOIDS/PARTS W/WO ARMATURES
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-765-5347

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each