NSN 5945-00-754-6611 MS24142D2, MS24142-D2, MILPRF6106
Product Details | ELECTROMAGNETIC RELAY
5945-00-754-6611 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: MS24142D2, MS24142-D2, MILPRF6106, MIL-PRF-6106, MILR6106, MIL-R-6106, 10137972 , 6042H152, 5945-00-754-6611, 00-754-6611, 5945007546611, 007546611
Electrical and Electronic Equipment Components | Relays and Solenoids
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1962 | 00-754-6611 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Demand History | NSN 5945-00-754-6611
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5945-00-754-6611 | 2024-10-288 | 6 | DIBBS |
MS24142D2 | 2024-02-32 | 1 | Germany |
5945-00-754-6611 | 2023-11-333 | 17 | DIBBS |
5945-00-754-6611 | 2023-08-236 | 14 | DIBBS |
MS24142D2 | 2022-01-20 | 2 | US |
MS24142D2 | 2021-12-349 | 1 | Taiwan |
5945-00-754-6611 | 2021-08-231 | 3 | DIBBS |
5945-00-754-6611 | 2021-07-210 | 7 | DIBBS |
5945-00-754-6611 | 2021-01-14 | 9 | DIBBS |
5945-00-754-6611 | 2020-10-303 | 12 | DIBBS |
5945-00-754-6611 | 2020-10-282 | 17 | DIBBS |
5945-00-754-6611 | 2020-07-203 | 13 | DIBBS |
5945-00-754-6611 | 2020-05-139 | 17 | DIBBS |
5945-00-754-6611 | 2020-05-128 | 17 | DIBBS |
5945-00-754-6611 | 2020-03-83 | 70 | DIBBS |
5945-00-754-6611 | 2020-03-68 | 70 | DIBBS |
5945-00-754-6611 | 2019-11-308 | 16 | DIBBS |
5945-00-754-6611 | 2019-10-297 | 16 | DIBBS |
MS24142D2 | 2019-09-262 | 1 | DE |
5945-00-754-6611 | 2018-11-309 | 26 | DIBBS |
5945-00-754-6611 | 2018-10-298 | 26 | DIBBS |
5945-00-754-6611 | 2018-10-288 | 46 | DIBBS |
5945-00-754-6611 | 2018-10-277 | 46 | DIBBS |
MS24142D2 | 2018-04-106 | 2 | United Arab Emirates |
MS24142D2 | 2016-05-124 | 1 | Egypt |
5945-00-754-6611 | 2013-05-139 | 61 | DIBBS |
5945-00-754-6611 | 2013-02-32 | 26 | DIBBS |
5945-00-754-6611 | 2012-08-244 | 44 | DIBBS |
MS24142D2 | 2012-07-195 | 2 | United States |
5945-00-754-6611 | 2012-06-181 | 14 | DIBBS |
5945-00-754-6611 | 2011-09-256 | 15 | DIBBS |
MS24142D2 | 2011-07-195 | 2 | United States |
5945-00-754-6611 | 2011-05-143 | 12 | DIBBS |
5945-00-754-6611 | 2011-02-56 | 28 | DIBBS |
5945-00-754-6611 | 2011-02-53 | 12 | DIBBS |
5945-00-754-6611 | 2011-01-25 | 16 | DIBBS |
6042H152 | 2008-06-179 | 6 | United States |
5945-00-754-6611 | 2007-11-319 | 50 | DIBBS |
5945-00-754-6611 | 2007-10-291 | 20 | DIBBS |
5945-00-754-6611 | 2007-03-80 | 10 | DIBBS |
5945-00-754-6611 | 2007-03-78 | 10 | DIBBS |
6042H152 | 2006-06-157 | 1 | US |
5945-00-754-6611 | 2006-05-147 | 10 | United States |
5945-00-754-6611 | 2006-05-137 | 22 | DIBBS |
Cross Reference | NSN 5945-00-754-6611
Part Number | Cage Code | Manufacturer |
---|---|---|
6042H152 | 15605 | EATON CORP OPNS & TECHNICAL CENTER |
6042H152 | 27192 | DRS POWER & CONTROL TECHNOLOGIES, INC. |
6042H152 | 81640 | EATON CORPORATION DBA FLUID POWER DIV |
MIL-PRF-6106 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-R-6106 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MS24142-D2 | 96906 | MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-754-6611
Related Products | NSN 5945-00-754-6611
Technical Data | NSN 5945-00-754-6611
Characteristic | Specifications |
---|---|
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 200.0 AMPERES AC AND 200.0 AMPERES DC RESISTIVE LOAD 100.0 AMPERES DC INDUCTIVE LOAD 150.0 AMPERES AC AND 200.0 AMPERES DC MOTOR LOAD |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD 5.0 AMPERES AC AND 5.0 AMPERES DC INDUCTIVE LOAD 750.0 MILLIAMPERES AC AND 750.0 MILLIAMPERES DC LAMP LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 52.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 THREADED STUD ALL FUNCTIONS |
TIME DELAY | 0.04 SECONDS MAXIMUM FIXED OPERATE TIME 0.015 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 3.640 INCHES MAXIMUM |
OVERALL WIDTH | 3.315 INCHES MAXIMUM |
OVERALL HEIGHT | 4.972 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.266 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION |
SPECIFICATION/STANDARD DATA | 96906-MS24142 GOVERNMENT STANDARD |
III PURPOSE FOR WHICH DESIGNED | GENERAL |
III CUBIC MEASURE | 60.755 CUBIC INCHES |
III UNPACKAGED UNIT WEIGHT | 2.500 POUNDS |
III FRAGILITY FACTOR | MODERATELY RUGGED |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
III CASE MATERIAL | METAL |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-6106 |
Restrictions/Controls & Freight Information | NSN 5945-00-754-6611
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-00-754-6611
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Price Validation | V | The current standard price has been validated.
|
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |