Product Details | ELECTRICAL SOLENOID

5945-00-723-4192 An item consisting of one or more coils surrounding an iron core. The coil(s) and the core are moveable in relation to each other. The axial or rotary movement is a result of the magnetic flux of the coil. It is designed to convert electrical energy into mechanical energy. It does not include switch contacts. See also RELAY, ELECTROMAGNETIC, and ELECTROMAGNETIC ACTUATOR.

Part Alternates: A36574001, A36574-001, 311205261REVB, 31-120526-1REVB, 5945-00-723-4192, 00-723-4192, 5945007234192, 007234192

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-723-4192

Drawings & Photos | NSN 5945-00-723-4192


Cross Reference | NSN 5945-00-723-4192

Part Number Cage Code Manufacturer
31-120526-1REVB 04655 GENERAL DYNAMICS C4 SYSTEMS, INC.
A36574-001 81840 SAIA-BURGESS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-723-4192

Technical Data | NSN 5945-00-723-4192

Characteristic Specifications
BODY STYLE 14 BASE END ACTUATOR
BODY DIAMETER 1.310 INCHES NOMINAL
BODY HEIGHT 0.844 INCHES NOMINAL
MAGNETIC COIL QUANTITY 1
VOLTAGE RATING IN VOLTS 170.0 AC MAXIMUM
CURRENT RATING 10.0 MILLIAMPERES NOMINAL
ELECTRICAL RESISTANCE 1.67 KILOHMS NOMINAL
DUTY TYPE CONTINUOUS
ACTUATOR STROKE TYPE PUSH
LINEAR FORCE DELIVERED 6.00 POUNDS
ENERGIZING STROKE MAXIMUM LENGTH 0.021 INCHES
POWER TAKEOFF CONNECTION TYPE PLAIN
ACTUATOR DIAMETER 0.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.875 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC MOUNTING FACILITY STUD
NOMINAL THREAD SIZE 0.125 INCHES MOUNTING FACILITY STUD
THREAD CLASS ANY ACCEPTABLE MOUNTING FACILITY STUD
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
TERMINAL LOCATION CIRCUMFERENCE
INCLOSURE TYPE FULLY INCLOSED
CASE MATERIAL STEEL
CASE SURFACE TREATMENT CADMIUM
ENVIRONMENTAL PROTECTION ANY ACCEPTABLE
III MAXIMUM OPERATING TEMP 70.0 DEG CELSIUS
MANUFACTURERS CODE 04655
DESIGN CONTROL REFERENCE 31-120526-1REVB

Restrictions/Controls & Freight Information | NSN 5945-00-723-4192

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063100 SOLENOIDS/PARTS W/WO ARMATURES
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-723-4192

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each