Product Details | ELECTROMAGNETIC RELAY

5945-00-553-9577 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: AN33112, AN3311-2, MILPRF6106, MIL-PRF-6106, MILR6106, MIL-R-6106, 14101550030, 1410-155003-0, 8538517, 5945-00-553-9577, 00-553-9577, 5945005539577, 005539577

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-553-9577

Demand History | NSN 5945-00-553-9577

Part Number Request Date QTY Origin
AN33112 2021-06-159 1 Malaysia
AN33112 2020-09-246 8 Malaysia
AN33112 2020-08-240 8 MY
5945-00-553-9577 2018-01-05 11 Malaysia
AN33112 2015-01-20 1 Malaysia
AN33112 2015-01-20 1 Malaysia
AN33112 2014-06-161 1 Malaysia
AN33112 2014-01-02 1 Malaysia
AN33112 2013-08-224 1 US
AN3311-2 2013-02-49 4 MY
AN33112 2011-03-88 1 US
AN33112 2011-02-48 4 US
AN33112 2007-11-332 1 LK

Cross Reference | NSN 5945-00-553-9577

Part Number Cage Code Manufacturer
1410-155003-0 73949 GUARDIAN ELECTRIC MANUFACTURING CO.
8538517 18876 U S ARMY AVIATION AND MISSILE COMMAND
AN3311-2 88044 AERONAUTICAL STANDARDS GROUP DEPT OF NAVY AND AIR FORCE
MIL-PRF-6106 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-6106 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-553-9577

Technical Data | NSN 5945-00-553-9577

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
NOMINAL OPERATING CURRENT RATING AND TYPE 200.0 MILLIAMPERES DC FIRST WINDING
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 2.600 INCHES NOMINAL
OVERALL WIDTH 2.500 INCHES NOMINAL
OVERALL HEIGHT 2.340 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER 0.208 INCHES NOMINAL SINGLE MOUNTING FACILITY
TEST DATA DOCUMENT 81349-MIL-R-6106 SPECIFICATION
SPECIFICATION/STANDARD DATA 88044-AN3311 GOVERNMENT STANDARD
MANUFACTURERS CODE 88044
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE AN3311-2
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-PRF-6106

Restrictions/Controls & Freight Information | NSN 5945-00-553-9577

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-553-9577

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each