Product Details | ELECTROMAGNETIC RELAY

5945-00-471-9789 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: 15506, 5945-00-471-9789, 00-471-9789, 5945004719789, 004719789

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 20 JAN 1971 00-471-9789

Cross Reference | NSN 5945-00-471-9789

Part Number Cage Code Manufacturer
15506 20183 DRS ICAS, LLC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-471-9789

Technical Data | NSN 5945-00-471-9789

Characteristic Specifications
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC AND 5.0 AMPERES DC INDUCTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 8.0 KILOHMS NOMINAL SINGLE WINDING
NOMINAL OPERATING CURRENT RATING AND TYPE 0.8 MILLIAMPERES DC SINGLE WINDING
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD ENERGIZING ELEMENT 3 PIN CONTACTS
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 2.064 INCHES NOMINAL
OVERALL WIDTH 1.440 INCHES NOMINAL
OVERALL HEIGHT 1.648 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-00-471-9789

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable