Product Details | ELECTROMAGNETIC RELAY

5945-00-394-1695 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: C74451Z1073U27, C74451-Z1073-U27, R10E1Y2V185, R10-E1-Y2-V185, VP2-CAB/14, VP2CAB14, 70000027001, 7000-0027-001, 5945-00-394-1695, 00-394-1695, 5945003941695, 003941695

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 05 APR 1974 00-394-1695

Cross Reference | NSN 5945-00-394-1695

Part Number Cage Code Manufacturer
7000-0027-001 06032 ANTENNA PRODUCTS CORPORATION
C74451-Z1073-U27 D1525 SIEMENS AG AUTOMATISIERUNGSTECHNIKAUT A13
R10-E1-Y2-V185 77342 TYCO ELECTRONICS CORPORATION
VP2-CAB/14 1E9M5 C P CLARE CORP
VP2-CAB/14 71482 CP CLARE CORP NORTH AMERICAN SALES OPERATIONS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-394-1695

Technical Data | NSN 5945-00-394-1695

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 3.0 AMPERES DC RESISTIVE LOAD
ARC QUENCHING METHOD AIR
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 52.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 10 TAB, SOLDER LUG ALL FUNCTIONS
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION DUSTPROOF
OVERALL LENGTH 0.938 INCHES MAXIMUM
OVERALL WIDTH 0.748 INCHES NOMINAL
OVERALL HEIGHT 1.187 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD FIRST MOUNTING FACILITY 1 PLUG-IN TERMINAL SECOND MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE FIRST MOUNTING FACILITY
THREAD SERIES DESIGNATOR UNC FIRST MOUNTING FACILITY
NOMINAL THREAD SIZE 0.099 INCHES FIRST MOUNTING FACILITY
THREAD CLASS 2A FIRST MOUNTING FACILITY
THREAD QUANTITY PER INCH 48 FIRST MOUNTING FACILITY
THREAD LENGTH 0.171 INCHES NOMINAL FIRST MOUNTING FACILITY
THREAD DIRECTION RIGHT-HAND FIRST MOUNTING FACILITY
III PURPOSE FOR WHICH DESIGNED GENERAL
III CUBIC MEASURE 0.832 CUBIC INCHES
III FRAGILITY FACTOR MODERATELY RUGGED
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III CONTACT MATERIAL SILVER
III PRECIOUS MATERIAL SILVER
III PRECIOUS MATERIAL AND LOCATION CONTACTS SILVER
MANUFACTURERS CODE 77342
DESIGN CONTROL REFERENCE R10-E1-Y2-V185

Restrictions/Controls & Freight Information | NSN 5945-00-394-1695

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code 48 Federal Aviation Administration
Oklahoma City, OK 73125
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-394-1695

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative