Product Details | ELECTROMAGNETIC RELAY

5945-00-010-1109 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: MV7244, 2046657105, 2046657-105, 2046657PC105, 5945-00-010-1109, 00-010-1109, 5945000101109, 000101109

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-010-1109

Cross Reference | NSN 5945-00-010-1109

Part Number Cage Code Manufacturer
2046657-105 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
2046657PC105 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
MV7244 03950 NAVAL INVENTORY CONTROL POINT MECHANICSBURG

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-010-1109

Technical Data | NSN 5945-00-010-1109

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY, TWO POSITIONS MAINTAINED
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 32.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES AC AND 2.0 AMPERES DC INDUCTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 2.5 KILOHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 55.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
NOMINAL OPERATING CURRENT RATING AND TYPE 11.0 MILLIAMPERES DC SINGLE WINDING
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
TIME DELAY 0.005 SECONDS NOMINAL FIXED OPERATE TIME 0.005 SECONDS NOMINAL FIXED RELEASE TIME
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 1.670 INCHES NOMINAL
OVERALL WIDTH 1.080 INCHES NOMINAL
OVERALL HEIGHT 0.730 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.060 INCHES NOMINAL SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-00-010-1109

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable