NSN 5935-00-259-2024 S2408SB, P7767096PT4, P776796734
Product Details | ELECTRICAL RECEPTACLE CONNECTOR
5935-00-259-2024 An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), PRINTED WIRING BOARD, or the like for convenience in joining with another electrical connector(s) or PRINTED WIRING BOARD. It is designed to be mounted on a bulkhead, chassis, panel, wall, PRINTED WIRING BOARD, or the like. Excludes LAMPHOLDER; JACK, TELEPHONE; JACK, TIP; INSERT ELECTRICAL CONNECTOR; INSERT MODULE, ELECTRICAL CONNECTOR; CONNECTOR BODY (as modified) and SOCKET, PLUG-IN ELECTRONIC COMPONENTS. See also WIRING HARNESS (as modified) and CABLE ASSEMBLY (as modified). For items with termination wires of more than four inches in length, see LEAD ASSEMBLY, ELECTRICAL. For items without inserts, see SHELL, ELECTRICAL CONNECTOR.
Part Alternates: S2408SB, P7767096PT4, P776796734, P7767-96734, 2641208012, 264-12-08-012, 516913, 5935-00-259-2024, 00-259-2024, 5935002592024, 002592024
Electrical and Electronic Equipment Components | Connectors, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-259-2024 | 15093 ( CONNECTOR, RECEPTACLE, ELECTRICAL ) |
Cross Reference | NSN 5935-00-259-2024
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5935-00-259-2024
Technical Data | NSN 5935-00-259-2024
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 2.812 INCHES NOMINAL |
OVERALL HEIGHT | 0.938 INCHES NOMINAL |
OVERALL WIDTH | 1.375 INCHES NOMINAL |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.375 INCHES NOMINAL |
UNTHREADED MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL |
SHELL TYPE | SOLID |
SHELL SURFACE TREATMENT | PAINT |
POLARIZATION METHOD | 2 POLARIZATION POSTS |
MATING END QUANTITY | 1 |
INSERT MATERIAL | PLASTIC POLYESTER SINGLE MATING END |
INCLUDED CONTACT QUANTITY | 8 SINGLE MATING END SINGLE CONTACT GROUPING |
CONTACT REMOVABILITY | NONREMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
INCLUDED CONTACT TYPE | FLAT SOCKET SINGLE MATING END SINGLE CONTACT GROUPING |
CONTACT MAXIMUM CURRENT RATING IN AMPS | 15.0 SINGLE MATING END SINGLE CONTACT GROUPING |
CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS | 1700.0 SINGLE MATING END SINGLE CONTACT GROUPING |
CONTACT MATERIAL | COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
CONTACT SURFACE TREATMENT | CADMIUM SINGLE MATING END SINGLE CONTACT GROUPING |
TERMINAL TYPE | TAB, SOLDER LUG SINGLE MATING END SINGLE CONTACT GROUPING |
TERMINAL LOCATION | BACK SINGLE MATING END SINGLE CONTACT GROUPING |
Restrictions/Controls & Freight Information | NSN 5935-00-259-2024
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061680 | ELEC WIRING PLUGS ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5935-00-259-2024
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |