Product Details | PRESSURE SWITCH

5930-01-494-6090 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Part Alternates: 1103P0448, 5930-01-494-6090, 01-494-6090, 5930014946090, 014946090

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 15 FEB 2002 01-494-6090

Drawings & Photos | NSN 5930-01-494-6090


Demand History | NSN 5930-01-494-6090

Part Number Request Date QTY Origin
5930-01-494-6090 2013-07-182 1 United States

Cross Reference | NSN 5930-01-494-6090

Part Number Cage Code Manufacturer
1103P0448 98087 ITT CORPORATION DBA ITT AEROSPACE CONTROLS UNIT S

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-494-6090

Technical Data | NSN 5930-01-494-6090

Characteristic Specifications
STYLE DESIGNATOR 41 CYLINDRICAL
OVERALL LENGTH 2.600 INCHES MAXIMUM
WIDTH ACROSS FLATS 0.680 INCHES NOMINAL
BODY LENGTH 1.488 INCHES NOMINAL
OVERALL DIAMETER 0.680 INCHES NOMINAL
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT VOLTAGE RATING IN VOLTS 28.0 DC AT SEA LEVEL SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 7.0 AMPERES RESISTIVE LOAD AND 4.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE
OPERATING TEMP RATING -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED LIQUID
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD INPUT PORT

Restrictions/Controls & Freight Information | NSN 5930-01-494-6090

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information