NSN 5930-01-494-6093 1103P92, 01-494-6093, 014946093
Product Details | PRESSURE SWITCH
5930-01-494-6093 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Part Alternates: 1103P92, 5930-01-494-6093, 01-494-6093, 5930014946093, 014946093
Electrical and Electronic Equipment Components | Switches
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 15 FEB 2002 | 01-494-6093 | 00206 ( SWITCH, PRESSURE ) |
Cross Reference | NSN 5930-01-494-6093
Part Number | Cage Code | Manufacturer |
---|---|---|
1103P92 | 98087 | ITT CORPORATION DBA ITT AEROSPACE CONTROLS UNIT S |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-494-6093
Related Products | NSN 5930-01-494-6093
Technical Data | NSN 5930-01-494-6093
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 41 CYLINDRICAL |
OVERALL LENGTH | 2.600 INCHES MAXIMUM |
WIDTH ACROSS FLATS | 0.680 INCHES NOMINAL |
BODY LENGTH | 1.488 INCHES NOMINAL |
OVERALL DIAMETER | 0.680 INCHES NOMINAL |
PRESSURE SWITCH TYPE | GAGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
CONTACT LOAD CURRENT RATING | 7.0 AMPERES RESISTIVE LOAD AND 4.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |
MOUNTING METHOD | INPUT PORT |
Restrictions/Controls & Freight Information | NSN 5930-01-494-6093
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |