Product Details | CIRCUIT BREAKER

5925-01-604-4008 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: IUGN6-1-52-10.0, IUGN6152100, 5925-01-604-4008, 01-604-4008, 5925016044008, 016044008

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 04 APR 2012 01-604-4008

Demand History | NSN 5925-01-604-4008

Part Number Request Date QTY Origin
IUGN6-1-52-10.0 2022-02-39 2 DIBBS
IUGN6-1-52-10.0 2019-01-23 4 DIBBS

Cross Reference | NSN 5925-01-604-4008

Part Number Cage Code Manufacturer
IUGN6-1-52-10.0 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-604-4008

Technical Data | NSN 5925-01-604-4008

Characteristic Specifications
NOMINAL THREAD SIZE 0.138 INCHES
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 7500.0 DC SINGLE LOCATION
TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
END ITEM IDENTIFICATION BOAT, RIGID I
TERMINAL TYPE AND QUANTITY 2 SCREW
THREAD QUANTITY PER INCH 32
BODY LENGTH 2.0 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC
BODY WIDTH 0.75 INCHES NOMINAL
POLE QUANTITY 1
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.66 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
BODY STYLE SINGLE POLE TYPE
ACTUATOR FUNCTION TRIP-RESET
RESET METHOD MANUAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES DC SINGLE LOCATION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.53 INCHES NOMINAL
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 1.2 NOMINAL AT 100 PCT SINGLE LOCATION
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.075 INCHES NOMINAL
CIRCUIT PROTECTION TYPE REVERSE CURRENT SINGLE LOCATION

Restrictions/Controls & Freight Information | NSN 5925-01-604-4008

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code HD Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-604-4008

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each