Product Details | CIRCUIT BREAKER

5925-01-599-2331 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: 482G212K1M1F6S050A, 482-G212-K1M1-F6S0-50A, 5925-01-599-2331, 01-599-2331, 5925015992331, 015992331

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 19-SEP-11 01-599-2331

Cross Reference | NSN 5925-01-599-2331

Part Number Cage Code Manufacturer
3113733C1 338X5 NAVISTAR DEFENSE LLC
482-G202-K1M1-F6S0-50A 3D8G0 E T A CIRCUIT BREAKERS DBA E T A PRODUCTS CO OF AMERICA
482-G212-K1M1-F6S0-50A 06402 OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS
482-G212-K1M1-F6S0-50A U0091 ETA CIRCUIT BREAKERS LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-599-2331

Technical Data | NSN 5925-01-599-2331

Characteristic Specifications
FREQUENCY IN HERTZ 400.0 SINGLE LOCATION
TRIP RELEASE METHOD SOLID STATE SINGLE LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
BODY LENGTH 1.22 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 2 SCREW
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC SINGLE LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
END ITEM IDENTIFICATION 2355015626152
POLE QUANTITY 1
BUSHING LENGTH 0.059 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 115.0 AC SINGLE LOCATION
BODY STYLE SINGLE POLE TYPE
PART NAME ASSIGNED BY CONTROLLING AGENCY THERMAL CIRCUIT BREAKER, HIGH PERFORMANCE
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.89 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.709 INCHES NOMINAL
BODY WIDTH 0.709 INCHES NOMINAL
RESET METHOD MANUAL

Restrictions/Controls & Freight Information | NSN 5925-01-599-2331

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information