NSN 5925-01-591-6121 FAZ-D10/2-NA, FAZD102NA, 01-591-6121
Product Details | CIRCUIT BREAKER
5925-01-591-6121 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Part Alternates: FAZ-D10/2-NA, FAZD102NA, 5925-01-591-6121, 01-591-6121, 5925015916121, 015916121
Electrical and Electronic Equipment Components | Circuit Breakers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 02 FEB 2011 | 01-591-6121 | 00136 ( CIRCUIT BREAKER ) |
Cross Reference | NSN 5925-01-591-6121
Part Number | Cage Code | Manufacturer |
---|---|---|
FAZ-D10/2-NA | 76526 | MOELLER INSTRUMENT COMPANY, INC. |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-01-591-6121
Technical Data | NSN 5925-01-591-6121
Characteristic | Specifications |
---|---|
MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
TERMINAL TYPE AND QUANTITY | 4 SCREW |
FREQUENCY IN HERTZ | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 20.000 AT 800 PCT PASCAL ALL LOCATIONS AND 90.000 18 STAGE PASCAL ALL LOCATIONS |
CASE MATERIAL | PLASTIC |
BODY WIDTH | 35.4 MILLIMETERS NOMINAL |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
SPECIAL FEATURES | SUITABLE FOR APPLICATIONS WHERE HIGH LEVELS OF INRUSH CURRENT ARE EXPECTED; PREVENTS NUISANCE TRIPPING IN HIGH INDUCTIVE APPS |
BODY HEIGHT | 44.0 MILLIMETERS NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 17.7 MILLIMETERS NOMINAL |
BODY LENGTH | 105.0 MILLIMETERS NOMINAL |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS AND 10000.0 DC ALL LOCATIONS |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
END ITEM IDENTIFICATION | AIRCRAFT C295 |
POLE QUANTITY | 2 |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 1000.0 ALL LOCATIONS |
INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP ALL LOCATIONS |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 277.0 AC ALL LOCATIONS AND 480.0 AC ALL LOCATIONS AND 96.0 DC ALL LOCATIONS |
TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS |
BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE ONE AND AT POLE TWO |
RESET METHOD | MANUAL |
PART NAME ASSIGNED BY CONTROLLING AGENCY | FAZ NA MINIATURE BRANCH CIRCUIT BREAKER FOR HIGHLY INDUCTIVE LOAD |
MOUNTING FACILITY TYPE AND QUANTITY | DIN RAIL |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS AND 10.0 AMPERES DC ALL LOCATIONS |
BOSS HEIGHT | 16.0 MILLIMETERS NOMINAL |
Restrictions/Controls & Freight Information | NSN 5925-01-591-6121
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |