Product Details | CIRCUIT BREAKER

5925-01-576-1619 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: AP112162752, AP112-1-62-752, 5925-01-576-1619, 01-576-1619, 5925015761619, 015761619

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 22 JUL 2009 01-576-1619

Demand History | NSN 5925-01-576-1619

Part Number Request Date QTY Origin
5925-01-576-1619 2022-03-81 147 Taiwan

Cross Reference | NSN 5925-01-576-1619

Part Number Cage Code Manufacturer
AP112-1-62-752 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-576-1619

Technical Data | NSN 5925-01-576-1619

Characteristic Specifications
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
PART NAME ASSIGNED BY CONTROLLING AGENCY MAGNETIC CIRCUIT PROTECTORS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY WIDTH 1.937 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNEF
THREAD QUANTITY PER INCH 32
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 7.5 AMPERES AC ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
BUSHING LENGTH 0.380 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 NOMINAL CENTIMETERS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
CASE MATERIAL METAL
FRAGILITY FACTOR MODERATELY RUGGED
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
BODY LENGTH 1.562 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
POLE QUANTITY 3
RESET METHOD MANUAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 NOMINAL CENTIMETERS
NOMINAL THREAD SIZE 0.375 INCHES
END ITEM IDENTIFICATION AN/BLQ10A (V) 1 SYSTEM
ACTUATOR POSITION DESIGNATION AT POLE TWO
SPECIAL HANDLING FEATURE MAGNETIC
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS

Restrictions/Controls & Freight Information | NSN 5925-01-576-1619

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code HD Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-576-1619

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each