Product Details | CIRCUIT BREAKER

5925-01-559-3358 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: AM1SA2AA07, AM1S-A2-A-A-07, 5019922230, 5019922-230 , 5925-01-559-3358, 01-559-3358, 5925015593358, 015593358

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 13 DEC 2007 01-559-3358

Cross Reference | NSN 5925-01-559-3358

Part Number Cage Code Manufacturer
5019922-230 K1182 THALES UK LIMITED DBA THALES UK LTDTRAINING AND SIMULATION
AM1S-A2-A-A-07 1Y502 HEINEMANN ELECTRIC CO INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-559-3358

Technical Data | NSN 5925-01-559-3358

Characteristic Specifications
POLE QUANTITY 1
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 480.0 AC AND 80.0 DC SINGLE LOCATION
FREQUENCY IN HERTZ 50.0 OR 60.0 SINGLE LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
RESET METHOD MANUAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION RESET

Restrictions/Controls & Freight Information | NSN 5925-01-559-3358

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information