NSN 5925-01-515-6301 AP12172103, AP-12-1-72-103, 01-515-6301
Product Details | CIRCUIT BREAKER
5925-01-515-6301 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Part Alternates: AP12172103, AP-12-1-72-103, 5925-01-515-6301, 01-515-6301, 5925015156301, 015156301
Electrical and Electronic Equipment Components | Circuit Breakers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 02 DEC 2003 | 01-515-6301 | 00136 ( CIRCUIT BREAKER ) |
Demand History | NSN 5925-01-515-6301
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5925-01-515-6301 | 2012-04-102 | 1 | NATO |
AP-12-1-72-103 | 2012-03-89 | 1 |
Cross Reference | NSN 5925-01-515-6301
Part Number | Cage Code | Manufacturer |
---|---|---|
AP-12-1-72-103 | 81541 | SENSATA TECHNOLOGIES MARYLAND, INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-01-515-6301
Technical Data | NSN 5925-01-515-6301
Characteristic | Specifications |
---|---|
POLE QUANTITY | 2 |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.200 MINIMUM AT 200 PCT AND 6.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
RESET METHOD | MANUAL |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BODY STYLE | 1B MULTIPOLE-SINGLE ACTUATOR TYPE |
BUSHING LENGTH | 0.380 INCHES MAXIMUM |
BODY LENGTH | 1.500 INCHES MAXIMUM |
BODY WIDTH | 1.250 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
CASE MATERIAL | METAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
THREAD SERIES DESIGNATOR | UNEF |
NOMINAL THREAD SIZE | 0.375 INCHES |
THREAD QUANTITY PER INCH | 32 |
TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
III NONTURN DEVICE LOCATION | AT 3 OCLOCK AND AT 9 OCLOCK |
III NONTURN DEVICE RADIUS | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
III NONTURN DEVICE LENGTH | 0.063 INCHES MINIMUM AND 0.125 INCHES MAXIMUM |
III NONTURN DEVICE DIAMETER | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
III SPECIAL HANDLING FEATURE | MAGNETIC |
III FRAGILITY FACTOR | MODERATELY RUGGED |
Restrictions/Controls & Freight Information | NSN 5925-01-515-6301
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |