Product Details | CIRCUIT BREAKER

5925-01-371-2876 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: AM4A3A3A3235402063, AM4A3A3A32-35-40-20-6-3, AM4S-A3A3A3A2-LAA02JDAW-52-35/40, AM4SA3A3A3A2LAA02JDAW523540, 69020360, 6902-0360, 5925-01-371-2876, 01-371-2876, 5925013712876, 013712876

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 10 FEB 1993 01-371-2876

Cross Reference | NSN 5925-01-371-2876

Part Number Cage Code Manufacturer
6902-0360 14304 HARRIS CORPORATION DBA HARRIS RF COMMUNICATION
AM4A3A3A32-35-40-20-6-3 74193 EATON CORP HEINEMANN PRODUCTS
AM4S-A3A3A3A2-LAA02JDAW-52-35/4- L3330 HEINEMANN ELECTRIC CANADA INCDIVISION OF EATON CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-371-2876

Technical Data | NSN 5925-01-371-2876

Characteristic Specifications
POLE QUANTITY 4
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 35.0 AMPERES AC FIRST LOCATION 40.0 AMPERES AC SECOND LOCATION 20.0 AMPERES AC THIRD LOCATION 6.0 AMPERES AC FOURTH LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS

Restrictions/Controls & Freight Information | NSN 5925-01-371-2876

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information