Product Details | CIRCUIT BREAKER

5925-01-020-3271 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: 5925-01-020-3271, 01-020-3271, 5925010203271, 010203271

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 01-020-3271

Drawings & Photos | NSN 5925-01-020-3271


Cross Reference | NSN 5925-01-020-3271

Part Number Cage Code Manufacturer
3020518-001 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
4116000-42 05869 RAYTHEON COMPANY DBA RAYTHEON
M39019-6-19 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39019/06-209 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-39019/6 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-PRF-39019/6G 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-020-3271

Technical Data | NSN 5925-01-020-3271

Characteristic Specifications
POLE QUANTITY 3
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 500.0 MILLIAMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3600.000 NOMINAL AT 100 PCT AND 0.200 MINIMUM AT 125 PCT AND 7.000 MAXIMUM AT 125 PCT AND 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.000 MINIMUM AT 400 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS 0.060 NOMINAL ALL LOCATIONS
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BUSHING LENGTH 0.280 INCHES MINIMUM AND 0.380 INCHES MAXIMUM
BODY LENGTH 1.562 INCHES MAXIMUM
BODY WIDTH 1.937 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.906 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.828 INCHES MAXIMUM
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
THREAD SERIES DESIGNATOR UNEF
NOMINAL THREAD SIZE 0.375 INCHES
THREAD QUANTITY PER INCH 32
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
MANUFACTURERS CODE 10001
DESIGN CONTROL REFERENCE 3020518-001

Restrictions/Controls & Freight Information | NSN 5925-01-020-3271

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information