Product Details | CIRCUIT BREAKER

5925-00-957-2897 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: A1088418G71, 240A61036, 240A610-36, 343L695MCG1, 5925-00-957-2897, 00-957-2897, 5925009572897, 009572897

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 00-957-2897

Drawings & Photos | NSN 5925-00-957-2897


Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-00-957-2897

Technical Data | NSN 5925-00-957-2897

Characteristic Specifications
POLE QUANTITY 3
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 350.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 600.0 AC ALL LOCATIONS
FREQUENCY IN HERTZ 50.0 OR 60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 22000.0 AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE UNDERVOLTAGE ALL LOCATIONS
TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 130.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS 2.000 NOMINAL ALL LOCATIONS
RESET METHOD ELECTRIC AND MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
RESET ACTUATOR VOLTAGE RATING AND TYPE IN VOLTS 125.0 AC AND 125.0 DC
BODY STYLE 21B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY LENGTH 10.125 INCHES NOMINAL
BODY WIDTH 8.250 INCHES NOMINAL
BODY HEIGHT 3.813 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 9.375 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 2.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 7.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 2.750 INCHES NOMINAL
BOSS HEIGHT 0.469 INCHES NOMINAL
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.390 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
TERMINAL TYPE AND QUANTITY 6 COMPRESSION
AUXILIARY SWITCH FUNCTION AND QUANTITY 3 CONTROL
MANUFACTURERS CODE 4A300
DESIGN CONTROL REFERENCE 343L695MCG1

Restrictions/Controls & Freight Information | NSN 5925-00-957-2897

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information