Product Details | CIRCUIT BREAKER

5925-00-396-2339 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: AQBA10050A, AQB-A100-50A, AQBA10050A60HZ, AQB-A100-50A-60HZ, ET56214, ETN4228, ETN43, ETN4922, G330023S1, MILC17361, MIL-C-17361, 1283793, 1299228, 1764699, 1773114, 305279PC50ATRIP, 5746201810906REVDPC43, 574-6201-810906REVDPC43, 5746201810907REVDPC31, 574-6201-810907REVDPC31, 9002562022298ALT4PC50ATRIP, 90025-6202-2298ALT4PC50ATRIP, 9002862022298ALT4PC50ATRIP, 90028-6202-2298ALT4PC50ATRIP, 5925-00-396-2339, 00-396-2339, 5925003962339, 003962339

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-396-2339

Drawings & Photos | NSN 5925-00-396-2339


Demand History | NSN 5925-00-396-2339

Part Number Request Date QTY Origin
MILC17361 2010-07-202 6 Taiwan
MILC17361 2010-07-202 12 Taiwan
5925-00-396-2339 2009-04-97 3 DIBBS
5925-00-396-2339 2008-06-161 3 DIBBS
5925-00-396-2339 2007-03-64 3 DIBBS

Cross Reference | NSN 5925-00-396-2339

Part Number Cage Code Manufacturer
1283793 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT
1299228 79500 WESTINGHOUSE ELECTRIC CORP
1764699 89946 EATON CORPORATION
1773114 79500 WESTINGHOUSE ELECTRIC CORP
305279PC50ATRIP 30086 SPD ELECTRICAL SYSTEMS, INC
574-6201-810906REVDPC43 80064 NAVAL SHIP SYSTEMS COMMAND
574-6201-810907REVDPC31 80064 NAVAL SHIP SYSTEMS COMMAND
90025-6202-2298ALT4PC50ATRIP 80064 NAVAL SHIP SYSTEMS COMMAND
90028-6202-2298ALT4PC50ATRIP 80064 NAVAL SHIP SYSTEMS COMMAND
AQB-A100-50A 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
AQB-A100-50A-60HZ 79500 WESTINGHOUSE ELECTRIC CORP
ET56214 30086 SPD ELECTRICAL SYSTEMS, INC
ETN4228 30086 SPD ELECTRICAL SYSTEMS, INC
ETN43 30086 SPD ELECTRICAL SYSTEMS, INC
ETN4922 30086 SPD ELECTRICAL SYSTEMS, INC
G330023S1 24930 EXELIS INC. DBA RADAR, RECONNAISSANCE & UNDERSEA
MIL-C-17361 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-00-396-2339

Technical Data | NSN 5925-00-396-2339

Characteristic Specifications
POLE QUANTITY 3
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 100.0 AMPERES AC AND 100.0 AMPERES DC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 500.0 AC AND 250.0 DC ALL LOCATIONS
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 7500.0 AC AND 10000.0 DC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TRIP RELEASE METHOD THERMAL-MAGNETIC ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS AND TIME DELAY ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 35.000 MINIMUM AT 600 PCT AND 45.000 MAXIMUM AT 600 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 10B MULTIPOLE-SINGLE ACTUATOR TYPE
BODY LENGTH 10.000 INCHES MAXIMUM
BODY WIDTH 5.000 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 8.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 8.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.625 INCHES NOMINAL
BOSS HEIGHT 0.125 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 8.407 INCHES NOMINAL
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.438 INCHES NOMINAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCK RESISTANT AND VIBRATION RESISTANT
SPECIAL FEATURES CIRCUIT BREAKER SUPPLIED WITH FOUR 1/4-20 MOUNTING SCREWS 1.812 IN. LG
TEST DATA DOCUMENT 81349-MIL-C-17361 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-C-17361 GOVERNMENT SPECIFICATION
III ARC QUENCHING METHOD AIR
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE

Restrictions/Controls & Freight Information | NSN 5925-00-396-2339

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-00-396-2339

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each