NSN 5920-01-496-4617 SMD050, SMD0502, SMD050-2
Product Details | ELECTRICAL FUSE LINK
5920-01-496-4617 An item which forms the replaceable fusible element of an electrical fuse and is prefabricated to a specific size and rating. It may be inclosed. See also FUSE, INCLOSED LINK and FUSE, OPEN LINK.
Part Alternates: SMD050, SMD0502, SMD050-2, SMD050F2, SMD050F-2 , 5920-01-496-4617, 01-496-4617, 5920014964617, 014964617
Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 16 APR 2002 | 01-496-4617 | 04185 ( FUSE LINK, ELECTRICAL ) |
Demand History | NSN 5920-01-496-4617
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5920-01-496-4617 | 2011-01-07 | 121 | DIBBS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5920-01-496-4617
Related Products | NSN 5920-01-496-4617
Technical Data | NSN 5920-01-496-4617
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 0.265 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
TERMINAL WIDTH | 0.125 INCHES MAXIMUM |
CONTINUOUS CURRENT RATING IN AMPS | 125.000 |
MAXIMUM VOLTAGE RATING IN VOLTS | 60.0 AC |
CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
INTERRUPTION INDICATOR METHOD | VISIBLE ELEMENT |
SPECIAL FEATURES | METALSURFACES ARE TIN PLATED,DIVICES CANNOT BE WAVE SOLDERD, OPERATION BEYOND THE RATED VOLTAGE OR CURRENT MAY RESULT IN RUPTURE OR ELECTRICAL ARCHING OR FLAME,POLYSWITCH,SURFACE-MOUNTED, RESETTABLE |
III END ITEM IDENTIFICATION | PRORACK 1,M-ELECT TEST EQUIP-GPETE,THIS POLY-SWITCH PCT DEVICES CAN HAVE THREE MAXIMUM ELECTRICAL RATINGS(OPERATING VOLTAGE/INTERRUP CURRENTS)EXAMPLE 60V/10A,12V/60A,5V/125A |
Restrictions/Controls & Freight Information | NSN 5920-01-496-4617
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 062060 | FUSES NOI IN BOXES |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5920-01-496-4617
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Physical Category Code | 1 | Bin |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |