Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-581-2401 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: MAL213658471E3, 222213658471, 2222-136-58471, 5910-01-581-2401, 01-581-2401, 5910015812401, 015812401

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 11 JAN 2010 01-581-2401

Cross Reference | NSN 5910-01-581-2401

Part Number Cage Code Manufacturer
2222-136-58471 56699 BC COMPONENTS
MAL213658471E3 56699 BC COMPONENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-581-2401

Technical Data | NSN 5910-01-581-2401

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 470.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -20.00 TO 20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 63.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND
BODY STYLE W/O MTG FACILITIES, TERMINAL(S) ON ONE END
BODY DIAMETER 16.0 MILLIMETERS NOMINAL
BODY LENGTH 25.0 MILLIMETERS NOMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 20.0 MILLIMETERS MINIMUM
CASE MATERIAL METAL
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES LEAD (PB) FREE, ROHS COMPLIANT

Restrictions/Controls & Freight Information | NSN 5910-01-581-2401

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information