Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-01-032-1823 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 39D886F150JE4, 430031, 43-0031, 5910-01-032-1823, 01-032-1823, 5910010321823, 010321823

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 10 DEC 1976 01-032-1823

Drawings & Photos | NSN 5910-01-032-1823


Cross Reference | NSN 5910-01-032-1823

Part Number Cage Code Manufacturer
39D886F150JE4 56289 SPRAGUE ELECTRIC CO WORLD HQS
43-0031 95750 AERONAUTICAL INSTRUMENT AND RADIO COMPANY, THE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-032-1823

Technical Data | NSN 5910-01-032-1823

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 88.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 50.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 150.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -20.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 1.062 INCHES NOMINAL
BODY LENGTH 1.250 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 2.500 INCHES MINIMUM
TERMINAL DIAMETER 0.040 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL ALUMINUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 18.0000
DC LEAKAGE AT REFERENCE TEMP 1.000 MILLIAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 1.250 INCHES NOMINAL
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 5.000 MILLIAMPERES
(NON-CORE DATA) OVERALL HEIGHT 1.062 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 1.062 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-01-032-1823

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-032-1823

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative