Product Details | MICA DIELECTRIC FIXED CAPACITOR

5910-00-144-2725 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: CM65FJ302GM1, MILC511, MILC5-11, 5910-00-144-2725, 00-144-2725, 5910001442725, 001442725

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 06 AUG 1969 00-144-2725

Drawings & Photos | NSN 5910-00-144-2725


Cross Reference | NSN 5910-00-144-2725

Part Number Cage Code Manufacturer
CM65FJ302GM1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILC5-11 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-144-2725

Technical Data | NSN 5910-00-144-2725

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 3000.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -2.00 TO 2.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 2000.0 AC-PEAK SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS 0.0 TO 70.0 SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 70.0 DEG CELSIUS MAXIMUM
BODY STYLE 5A W/MTG TABS/FLANGES, TERMINAL(S) ON ONE SURFACE
BODY LENGTH 2.030 INCHES NOMINAL
BODY WIDTH 0.940 INCHES NOMINAL
BODY HEIGHT 1.470 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED MOUNTING HOLES
UNTHREADED MOUNTING HOLE DIAMETER 0.170 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.375 INCHES NOMINAL
INSULATION RESISTANCE AT REFERENCE TEMP 7500.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.0150
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 81349-MIL-C-5/11 SPECIFICATION
III MAXIMUM RF CURRENT RATING AT HIGHEST RATED FREQUENCY IN RMS AMPS 7.5
III HIGHEST FREQUENCY AT WHICH RF CURRENT RATING APPLIES IN KILOHERTZ 3000.0
III MAXIMUM RF CURRENT RATING AT LOWEST RATED FREQUENCY IN RMS AMPS 1.3
III LOWEST FREQUENCY AT WHICH RF CURRENT RATING APPLIES IN KILOHERTZ 100.0
III INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 2000.0 MEGOHMS
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE CM65FJ302GM1
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILC5-11

Restrictions/Controls & Freight Information | NSN 5910-00-144-2725

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-144-2725

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each