NSN 5910-00-140-0091 M39006094219, M39006-09-4219, MILC390069
Product Details | ELECTROLYTIC FIXED CAPACITOR
5910-00-140-0091 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Part Alternates: M39006094219, M39006-09-4219, MILC390069, MILC39006-9, 5910-00-140-0091, 00-140-0091, 5910001400091, 001400091
Electrical and Electronic Equipment Components | Capacitors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 SEP 1971 | 00-140-0091 | 00008 ( CAPACITOR, FIXED, ELECTROLYTIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-00-140-0091
Related Products | NSN 5910-00-140-0091
Technical Data | NSN 5910-00-140-0091
Characteristic | Specifications |
---|---|
CAPACITANCE VALUE PER SECTION | 330.000 MICROFARADS SINGLE SECTION |
TOLERANCE RANGE PER SECTION | -10.00 TO 10.00 PERCENT SINGLE SECTION |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 6.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
BODY STYLE | 26B W/O MTG FACILITIES, AXIAL TERMINALS |
BODY DIAMETER | 0.406 INCHES MAXIMUM |
BODY LENGTH | 0.844 INCHES NOMINAL |
SCHEMATIC DIAGRAM DESIGNATOR | 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TERMINAL LENGTH | 2.250 INCHES NOMINAL |
CASE MATERIAL | METAL |
CASE INSULATION MATERIAL | PLASTIC |
CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 49.6000 |
POWER FACTOR AT REFERENCE TEMP IN PERCENT | 20.0000 |
DC LEAKAGE AT REFERENCE TEMP | 2.000 MICROAMPERES |
ELECTRICAL POLARIZATION | POLARIZED |
RELIABILITY INDICATOR | ESTABLISHED |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
TEST DATA DOCUMENT | 81349-MILC39006 SPECIFICATION AND 81349-MILC39006-9 SPECIFICATION |
III MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | AN-3 AND C |
III TERMINAL SURFACE TREATMENT | SOLDER |
III ANODE TYPE | SOLID |
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS | 20.0 |
III DC LEAKAGE AT MAXIMUM OPERATING TEMP | 7.9 MILLIAMPERES |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILC39006-9 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39006-09-4219 |
Restrictions/Controls & Freight Information | NSN 5910-00-140-0091
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
Less than car load rating | P | 77.5 |
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-00-140-0091
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |