Product Details | ELECTROLYTIC FIXED CAPACITOR

5910-00-114-0070 A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: M39006/01-3068, M39006013068, MILC390061, MILC39006-1, 122D117C7030J1, 2351610P13, 235-1610P13, 5910-00-114-0070, 00-114-0070, 5910001140070, 001140070

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 22 FEB 1973 00-114-0070

Drawings & Photos | NSN 5910-00-114-0070


Cross Reference | NSN 5910-00-114-0070

Part Number Cage Code Manufacturer
122D117C7030J1 56289 SPRAGUE ELECTRIC CO WORLD HQS
235-1610P13 49956 RAYTHEON COMPANY DBA RAYTHEON
M39006/01-3068 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILC39006-1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-114-0070

Technical Data | NSN 5910-00-114-0070

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 110.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -15.00 TO 75.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 30.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.406 INCHES MAXIMUM
BODY LENGTH 1.516 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES NOMINAL
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CASE MATERIAL METAL
CASE INSULATION MATERIAL PLASTIC
CAPACITIVE ELECTRODE MATERIAL TANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 20.0000
DC LEAKAGE AT REFERENCE TEMP 4.000 MICROAMPERES
ELECTRICAL POLARIZATION POLARIZED
RELIABILITY INDICATOR ESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT 0.1000
FEATURES PROVIDED HERMETICALLY SEALED CASE
TEST DATA DOCUMENT 81349-MIL-C-39006 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-C-39006/1 GOVERNMENT SPECIFICATION
III MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR N-3
III ANODE TYPE ETCHED FOIL
III IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS 31.0
(NON-CORE DATA) OVERALL LENGTH 1.938 INCHES MAXIMUM
III DC LEAKAGE AT MAXIMUM OPERATING TEMP 50.0 MICROAMPERES
(NON-CORE DATA) OVERALL HEIGHT 0.406 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.406 INCHES MAXIMUM
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILC39006-1
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M39006/01-3068

Restrictions/Controls & Freight Information | NSN 5910-00-114-0070

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-114-0070

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each