Product Details | FILM FIXED RESISTOR NETWORK

5905-01-407-1042 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.

Part Alternates: M8340109K3001JC, MIL-R-83401/9, MILR834019, 5905-01-407-1042, 01-407-1042, 5905014071042, 014071042

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 20 JAN 1995 01-407-1042

Drawings & Photos | NSN 5905-01-407-1042


Cross Reference | NSN 5905-01-407-1042

Part Number Cage Code Manufacturer
M8340109K3001JC 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-83401/9 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-407-1042

Technical Data | NSN 5905-01-407-1042

Characteristic Specifications
ELECTRICAL RESISTANCE 3.000 KILOHMS
IDENTICAL VALUE RESISTOR QUANTITY 9 EACH RESISTOR
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000
POWER DISSIPATION RATING IN WATTS 1.080 TOTAL NETWORK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 70.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 125.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -100.0 TO 100.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 125.0
SCHEMATIC DIAGRAM DESIGNATOR 3 LADDER NETWORK
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 218 SINGLE INLINE
BODY LENGTH 0.968 INCHES MINIMUM AND 0.998 INCHES MAXIMUM
BODY WIDTH 0.050 INCHES MINIMUM AND 0.103 INCHES MAXIMUM
BODY HEIGHT 0.177 INCHES MINIMUM AND 0.197 INCHES MAXIMUM
TERMINAL TYPE PIN
TERMINAL QUANTITY 10
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 0.125 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
TEST DATA DOCUMENT 81349-MIL-R-83401 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-83401/9 GOVERNMENT SPECIFICATION
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-R-83401/9
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M8340109K3001JC

Restrictions/Controls & Freight Information | NSN 5905-01-407-1042

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-01-407-1042

Category Code Description
Materiel Management Aggregation CodeBATB:C-17 PROGRAM
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Budget CodeS 1557X3010:Aircraft Replenishment Spares
Source of SupplyF77Boeing Military Transportation Aircraft
Los Angeles, CA 90307-3044
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesMRESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) # Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative