Product Details | FILM FIXED RESISTOR NETWORK

5905-01-226-8296 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.

Part Alternates: M8340101M6810FB, MIL-R-83401/1, MILR834011, 5905-01-226-8296, 01-226-8296, 5905012268296, 012268296

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 24 FEB 1986 01-226-8296

Drawings & Photos | NSN 5905-01-226-8296


Cross Reference | NSN 5905-01-226-8296

Part Number Cage Code Manufacturer
M8340101M6810FB 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-R-83401/1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-226-8296

Technical Data | NSN 5905-01-226-8296

Characteristic Specifications
ELECTRICAL RESISTANCE 681.000 OHMS
IDENTICAL VALUE RESISTOR QUANTITY 13 EACH RESISTOR
RESISTANCE TOLERANCE IN PERCENT -1.000 TO 1.000
POWER DISSIPATION RATING IN WATTS 1.625 TOTAL NETWORK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 70.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 125.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -300.0 TO 300.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 125.0
SCHEMATIC DIAGRAM DESIGNATOR 2 LADDER NETWORK
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 220 DUAL INLINE
BODY LENGTH 0.740 INCHES NOMINAL
BODY WIDTH 0.270 INCHES NOMINAL
BODY HEIGHT 0.135 INCHES MAXIMUM
TERMINAL TYPE TAB, SOLDER LUG
TERMINAL QUANTITY 14
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 0.135 INCHES NOMINAL
TERMINAL WIDTH 0.015 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
TEST DATA DOCUMENT 81349-MIL-R-83401 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-R-83401/1 GOVERNMENT SPECIFICATION
III END ITEM IDENTIFICATION AN/BPS14TO15E
III UNPACKAGED UNIT WEIGHT 1.3 GRAMS
(NON-CORE DATA) CUBIC MEASURE 0.040 CUBIC INCHES
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-R-83401/1
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M8340101M6810FB

Restrictions/Controls & Freight Information | NSN 5905-01-226-8296

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5905-01-226-8296

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each