NSN 5905-01-022-5238 CAT17677, GN807AB223G, GN807AB-223G
Product Details | FILM FIXED RESISTOR NETWORK
5905-01-022-5238 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.
Part Alternates: CAT17677, GN807AB223G, GN807AB-223G, V22211Z8A27, V22211-Z8-A27, 36D2234, 4116R001223, 4116R-001-223, 52000410, 9999220202, 9999-2202-02, 5905-01-022-5238, 01-022-5238, 5905010225238, 010225238
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 30 MAY 1976 | 01-022-5238 | 32068 ( RESISTOR NETWORK, FIXED, FILM ) |
Cross Reference | NSN 5905-01-022-5238
Part Number | Cage Code | Manufacturer |
---|---|---|
36D2234 | 01121 | ROCKWELL AUTOMATION, INC. |
4116R-001-223 | 80294 | BOURNS INSTRUMENTS INC |
52000410 | C4542 | ROHDE & SCHWARZ GMBH & CO. KGSERVICE OPERATION WEST |
9999-2202-02 | 75042 | TRW INC TRW ELECTRONIC COMPONENTS |
CAT17677 | U2089 | NICE CTI SYSTEMS UK LTD |
GN807AB-223G | 26512 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE |
V22211-Z8-A27 | C0363 | NOKIA SOLUTIONS AND NETWORKS GMBH &CO. KG |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5905-01-022-5238
Technical Data | NSN 5905-01-022-5238
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 22.000 KILOHMS |
IDENTICAL VALUE RESISTOR QUANTITY | 8 EACH RESISTOR |
RESISTANCE TOLERANCE IN PERCENT | -2.000 TO 2.000 |
POWER DISSIPATION RATING IN WATTS | 1.500 TOTAL NETWORK |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 65.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
SCHEMATIC DIAGRAM DESIGNATOR | 1 ISOLATED ARRAY |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 220 DUAL INLINE |
BODY LENGTH | 0.860 INCHES MAXIMUM |
BODY WIDTH | 0.260 INCHES MAXIMUM |
BODY HEIGHT | 0.100 INCHES NOMINAL |
TERMINAL TYPE | PIN |
TERMINAL QUANTITY | 16 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
TERMINAL LENGTH | 0.135 INCHES MINIMUM |
Restrictions/Controls & Freight Information | NSN 5905-01-022-5238
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062960 | REOSTATS/PARTS NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5905-01-022-5238
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |