NSN 5905-00-219-7049 MILR551823, MILR55182-3, RNC60H1182BP
Product Details | FILM FIXED RESISTOR
5905-00-219-7049 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of either a thin layer of conductive material, containing either binders or insulating materials, deposited on an insulated form; or an alloy of metal and ceramic materials, usually fused to an insulated form. Opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the resistor. See also ATTENUATOR, FIXED and RESISTOR, FIXED, COMPOSITION. Excludes carbon composition type resistors.
Part Alternates: MILR551823, MILR55182-3, RNC60H1182BP, RNC60H1182BS, RNC60H1182CS, RNR60H1182BS, 5905-00-219-7049, 00-219-7049, 5905002197049, 002197049
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 09 MAY 1973 | 00-219-7049 | 05311 ( RESISTOR, FIXED, FILM ) |
Cross Reference | NSN 5905-00-219-7049
Part Number | Cage Code | Manufacturer |
---|---|---|
MILR55182-3 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNC60H1182BP | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNC60H1182BS | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNC60H1182CS | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNR60H1182BS | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5905-00-219-7049
Technical Data | NSN 5905-00-219-7049
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 11.800 KILOHMS |
RESISTANCE TOLERANCE IN PERCENT | -0.100 TO 0.100 |
POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 175.0 |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 14 AXIAL TERMINAL EACH END |
BODY DIAMETER | 0.125 INCHES NOMINAL |
BODY LENGTH | 0.375 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
RELIABILITY INDICATOR | ESTABLISHED |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
TEST DATA DOCUMENT | 81349-MILR55182 SPECIFICATION |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILR55182-3 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RNC60H1182BS |
Restrictions/Controls & Freight Information | NSN 5905-00-219-7049
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062960 | REOSTATS/PARTS NOI |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5905-00-219-7049
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |