Product Details | RESISTOR ASSEMBLY

5905-00-218-0464 Two or more individual fixed, variable, thermal, or adjustable resistors on a common mounting or mounted on each other. The resistors must be separable and each must be capable of functioning in accordance with its applicable item name. For variable resistors mounted in tandem with a common or dual concentric shaft, see RESISTOR, VARIABLE (as modified) and ATTENUATOR, VARIABLE. For inseparable resistors permanently cased, sealed or potted together to form a multisection unit, see RESISTOR ASSORTMENT; RESISTOR SET, MATCHED; and items which have wire leads temporarily twisted together, or are otherwise physically attached solely for convenience in handling or shipping.

Part Alternates: K41506650, K41506-650, 2880162G5, 5905-00-218-0464, 00-218-0464, 5905002180464, 002180464

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-218-0464

Cross Reference | NSN 5905-00-218-0464

Part Number Cage Code Manufacturer
2880162G5 03497 GENERAL ELECTRIC CO OUTDOOR BREAKER BUSINESS SECTION
K41506-650 63743 WARD LEONARD ELECTRIC COMPANY INC.
K41506-650 71669 GENERAL ELECTRIC CO SWITCHGEAR AND CONTROL DIVISION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-218-0464

Technical Data | NSN 5905-00-218-0464

Characteristic Specifications
ASSEMBLY CONSTRUCTION METHOD MOUNTED BETWEEN L-BRACKETS
COMPONENT RELATIONSHIP NOT MATCHED
COMPONENT QUANTITY 2
COMPONENT NAME FIXED WIRE WOUND TYPE
COMPONENT CONTROLLING AGENCY WARD LEONARD ELECTRIC CO
COMPONENT IDENTIFYING NUMBER K-41506-1 DRAWING NO.
ELECTRICAL RESISTANCE 650.000 OHMS
RESISTANCE TOLERANCE IN PERCENT -10.0 TO 10.0
RESISTOR POWER DISSIPATION RATING IN WATTS 170.00
MOUNTING METHOD BRACKET
MOUNTING CONFIGURATION TWO 0.281 IN. BY 0.563 IN. SLOTS SPACED 8.375 IN. TO 8.938 IN. C TO C
MANUFACTURERS CODE 63743
DESIGN CONTROL REFERENCE K41506-650

Restrictions/Controls & Freight Information | NSN 5905-00-218-0464

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-00-218-0464

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each