NSN 5905-00-166-5730 MF4CD32R8F, A069891001, A0698-9100-1
Product Details | FILM FIXED RESISTOR
5905-00-166-5730 A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of either a thin layer of conductive material, containing either binders or insulating materials, deposited on an insulated form; or an alloy of metal and ceramic materials, usually fused to an insulated form. Opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the resistor. See also ATTENUATOR, FIXED and RESISTOR, FIXED, COMPOSITION. Excludes carbon composition type resistors.
Part Alternates: MF4CD32R8F, A069891001, A0698-9100-1, C432R8F, C4-32R8F, CMF-55-18 32R8F T-1, CMF551832R8FT1, CMF55X018F32R80F, PME55T032R80F, PME55T0-32R80F, 06984090, 0698-4090, 5905-00-166-5730, 00-166-5730, 5905001665730, 001665730
Electrical and Electronic Equipment Components | Resistors
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 00-166-5730 | 05311 ( RESISTOR, FIXED, FILM ) |
Cross Reference | NSN 5905-00-166-5730
Part Number | Cage Code | Manufacturer |
---|---|---|
0698-4090 | 1MY97 | AGILENT TECHNOLOGIES, INC. DIV AGILENT TECHNOLOGIES |
0698-4090 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
193219 | 89536 | FLUKE CORPORATION |
321-0051-00 | 80009 | TEKTRONIX, INC. DBA TEKTRONIX |
4701-03-3329 | 23338 | WAVETEK U S INC DIV OF WAVETEK CORP |
5043ED33R20F | 19701 | NORTH AMERICAN PHILIPS CORP PHILIPS COMPONENTS |
528042 | 04901 | BOONTON ELECTRONICS CORPORATION DIV BOONTON ELECTRONICS |
69-032679-096 | 32791 | THOMSON MULTIMEDIA BROADCAST SOLUTIONS INC |
705-0925-000 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
A0698-9100-1 | 1MY97 | AGILENT TECHNOLOGIES, INC. DIV AGILENT TECHNOLOGIES |
A0698-9100-1 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
C4-32R8F | 24546 | DALE ELECTRONICS INC A VISHAY INTERTECHOLOGY INC CO |
CMF-55-116D33R20F | 91637 | VISHAY DALE ELECTRONICS, INC. DIV VISHAY ANGSTROHM & DALE |
CMF-55-18 32R8F T-1 | 91637 | VISHAY DALE ELECTRONICS, INC. DIV VISHAY ANGSTROHM & DALE |
CMF55X018F32R80F | 91637 | VISHAY DALE ELECTRONICS, INC. DIV VISHAY ANGSTROHM & DALE |
FE10 | 80031 | MEPCO/ELECTRA INC |
MF4CD32R8F | 19701 | NORTH AMERICAN PHILIPS CORP PHILIPS COMPONENTS |
MIL-R-55182/1 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
NA55D33R2F | 14674 | CORNING GLASS WORKS |
NA55D33R2F | 18612 | VISHAY INTERTECHNOLOGY, INC. DBA VISHAY AMERICAS |
PME55T0-32R80F | 64537 | AEROFLEX CONTROL COMPONENTS, INC. DBA AEROFLEX / KDI |
RN55D33R0F | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RN55D33R2F | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNC55K33R2FM | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNC55K33R2FS | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNR55K33R2FS | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
RNR55K33R2FTX | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
T055-33R2-1F | 11502 | INTERNATIONAL RESISTIVE COMPANY INC. |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5905-00-166-5730
Technical Data | NSN 5905-00-166-5730
Characteristic | Specifications |
---|---|
ELECTRICAL RESISTANCE | 32.800 OHMS |
RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0 TO 100.0 |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 165.0 |
INCLOSURE METHOD | ENCAPSULATED |
STYLE DESIGNATOR | 14 AXIAL TERMINAL EACH END |
BODY DIAMETER | 0.100 INCHES NOMINAL |
BODY LENGTH | 0.281 INCHES NOMINAL |
TERMINAL TYPE | WIRE LEAD |
RELIABILITY INDICATOR | NOT ESTABLISHED |
Restrictions/Controls & Freight Information | NSN 5905-00-166-5730
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Category | Code | Description |
---|---|---|
No Freight Information |